Folder AE Technical Bulletins (by Doc #)

For Telephone Sets and other Customer Equipment.  Go to the Bruce Crawford Library for Bulletins dealing with Switching, Signaling, and Test Equipment.

Documents

AE TB 500 i7 1961 - Operating and Service Records for Automatic Telephone Plants Popular

By 723 downloads

Download (pdf, 1.64 MB)

AE_TB_500_i7_1961_Operating_and_Service_Records_for_Automatic_Telephone_Plants_ocr_tci.pdf

AE TB 500 i7 1961 - Operating and Service Records for Automatic Telephone Plants

Technical Bulletin. Contributed and scanned by John Novack. Processed by Paul Fassbender.

AE TB 505 i7 - Lubrication of Automatic Switching Equipment Popular

By 872 downloads

Download (pdf, 919 KB)

AE_TB_505_i7_Lubrication_of_Automatic_Switching_Equipment_ocr_tci.pdf

AE TB 505 i7 - Lubrication of Automatic Switching Equipment

Technical Bulletin (undated). Contributed and scanned by John Novack. Processed by Paul Fassbender.

AE TB 505 i9 1961 - Lubrication of Automatic Switching Equipment Popular

By 1152 downloads

Download (pdf, 1.80 MB)

AE_TB_505_i9_1961_Lubrication_of_Automatic_Switching_Equipment_ocr_tci.pdf

AE TB 505 i9 1961 - Lubrication of Automatic Switching Equipment

Technical Bulletin. Contributed and scanned by John Novack. Processed by Paul Fassbender.

AE TB 538 i3 1961 - Adjustment of Type 57 A and Type 58 A Relays Popular

By 968 downloads

Download (pdf, 1.77 MB)

AE_TB_538_i3_1961_Adjustment_of_Type-57-A_and_Type-58-A_Relays_ocr_tci.pdf

AE TB 538 i3 1961 - Adjustment of Type 57 A and Type 58 A Relays

Technical Bulletin. Contributed and scanned by John Novack. Processed by Paul Fassbender.

AE TB 565 i1 1961 - General Maintenance of PAXs Popular

By 973 downloads

Download (pdf, 2.37 MB)

AE_TB_565_i1_1961_General_Maintenance_of_PAXs_ocr_tci.pdf

AE TB 565 i1 1961 - General Maintenance of PAXs

Contributed by John Novack.

AE TB 700-82 Jun55 - Monophone Type-80 Conversion to 2-Tone Color Popular

By 728 downloads

Download (pdf, 171 KB)

AE_TB_700-82_Jun55_Monophone_Type_80_Conversion_to_2-Tone_Color_tci_ocr.pdf

AE TB 700-82 Jun55 - Monophone Type-80 Conversion to 2-Tone Color

Contributed by Paul Fassbender.

AE TB 701-85 i2 Sep58 - AE Type-85 Set - Tl Popular

By 2440 downloads

Download (pdf, 3.31 MB)

AECo Bulletin 701-85 Type 85 Set_tl.pdf

AE TB 701-85 i2 Sep58 - AE Type-85 Set - Tl

Sept 58.  Keyset, 2-line. Small format. Bookmarked.

 

AE TB 840-349 i3 1962 - Portable 500-line Trafficorder Popular

By 967 downloads

Download (pdf, 1.11 MB)

AE_TB_840-349_i3_1962_Portable_500-line_Trafficorder_ocr_tci.pdf

AE TB 840-349 i3 1962 - Portable 500-line Trafficorder

Contributed by John Novack.

AE TB 960-401 i3 1962 - Emergency Reporting System Popular

By 1034 downloads

Download (pdf, 1.71 MB)

AE_TB_960-401_i3_1962_Emergency_Reporting_System_ocr_tci.pdf

AE TB 960-401 i3 1962 - Emergency Reporting System

Contributed by John Novack.

AE TB 961 537 i4 1961 - Relays Type 57A and Type 58 A Popular

By 1037 downloads

Download (pdf, 1.52 MB)

AE_TB_961-537_i4_1961_Relays_Type-57A_and_Type_58-A_ocr_tci.pdf

AE TB 961 537 i4 1961 - Relays Type 57A and Type 58 A

Technical Bulletin. Contributed and scanned by John Novack. Processed by Paul Fassbender.

AE TB 961-473 i8 1961 - Rotary Stepping Switches Popular

By 1066 downloads

Download (pdf, 4.19 MB)

AE_TB_961-473_i8_1961_Rotary_Stepping_Switches_ocr_tci.pdf

AE TB 961-473 i8 1961 - Rotary Stepping Switches

Technical Bulletin. Contributed and scanned by John Novack. Processed by Paul Fassbender.

AE Technical bulletin 700 43 Monophone Type 43 Installation April 1956 Popular

By 1261 downloads

Download (pdf, 3.94 MB)

AE_Technical_bulletin_700-43_-_Monophone_Type_43_Installation_April_1956.pdf

AE Technical bulletin 700 43   Monophone Type 43 Installation April 1956

Contributed by Remco Enthoven. Scanned by Gary Goff.

TB 470-916 i3 1962 - Type-880 Speakerphone Popular

By 2024 downloads

Download (pdf, 20.28 MB)

TB 470-916 - Type-880 Speakerphone.pdf

TB 470-916 i3 1962 - Type-880 Speakerphone

Technical Bulletin issue 3 includes Installation, Maintenance and a schematic.

TB 470-916 i3 1962 - Type-880 Speakerphone (small) Popular

By 2051 downloads

Download (pdf, 1.15 MB)

TB 470-916 ~ Type-880 Speakerphone (small).pdf

TB 470-916 i3 1962 - Type-880 Speakerphone (small)

Technical Bulletin issue 3 includes Installation, Maintenance and a schematic.

TB 700-80 I5 - AE Type-80 Telephone Popular

By 2012 downloads

Download (pdf, 4.42 MB)

AECo Bulletin 700-80 Type-80 Telephone.pdf

TB 700-80 I5 - AE Type-80 Telephone

Issue 5, Jun58  June 1958

TB 700-80 I5 - AE Type-80 Telephone - Tl Popular

By 2040 downloads

Download (pdf, 4.42 MB)

AECo Bulletin 700-80 Type-80 Telephone_tl.pdf

TB 700-80 I5 - AE Type-80 Telephone - Tl
June 58. Type-80 Installation and Adjustment.

TB 700-90M I1 - AE Type-90 Wall Set Popular

By 2329 downloads

Download (pdf, 10.96 MB)

AECo Bulletin 700-90MType 90 Wall Set Practice.pdf

TB 700-90M I1 - AE Type-90 Wall Set

Issue 1, Jun59   June 1959

TB 700-90M I1 - AE Type-90 Wall Set - Tl Popular

By 2062 downloads

Download (pdf, 4.26 MB)

AECo Bulletin 700-90MType 90 Wall Set Practice_tl.pdf

TB 700-90M I1 - AE Type-90 Wall Set - Tl
June 59. Wall Set.

TB 701-80 I1 - AE 80 Hard of Hearing Set - Tl Popular

By 1816 downloads

Download (pdf, 3.71 MB)

AECo Bulletin 701-80 - H-o-H Set_tl.pdf

TB 701-80 I1 - AE 80 Hard of Hearing Set - Tl
July 58. AE 80 with integrated transistorized amplifier.

TB 701-80 I1 - AE Type 80, Transistorized Amp (Hard of Hearing) Popular

By 1746 downloads

Download (pdf, 3.71 MB)

AECo Bulletin 701-80 - H-o-H Set.pdf

TB 701-80 I1 - AE Type 80, Transistorized Amp (Hard of Hearing)

Technical Bulletin 701-80
Issue 1, July 1958

HARD OF HEARING
TELEPHONE TYPE 80
(TRANSISTORIZED)

INSTALLATION AND ADJUSTMENTS ?

1. DESCRIPTION
The type 80 Transistorized Telephone employs a transistor amplifier in
the receiving circuit for the purpose of aiding hard of hearing
subscribers. The Type 80 Transistorized Telephone is a self contained
desk set; no separate ringer box is necessary.
The set is equipped with a volume control and a 3-conductor line cord
which terminates in a small plastic 3-conductor connecting-block. The
connecting-block accepts wiring for either bridged or divided ringing.
No soldering is required. Telephone can be used on only 48-volt systems.

2. TRANSISTOR AMPLIFIER
The Type 80 Transistorized Telephone has a printed circuit amplifier
(page 28) ; no attempt should be made to repair it in the field. Remove
the printed wire board and replace it with a new one. (Order D-35290-A
as replacement board.)

New User?

Read the articles under "Introduction" in the black menu bar above.

Recent Contributors

Thanks for new documents from Ed Palazzo, Bruce Patterson, Jon Kolger, Paul Ivester, Len Hicken, Paul Fassbender, Fred Haynes, Kurt Rudolph, Wade ("Kellogg KITT"), the Connections Museum, Rick Walsh, Jeff Lamb, Jeremy Walters, Mark Cuccia, Alan David, Harry Joseph, Charlie Terry, Karl Brose, Dennis Hock, Tim Griffin, Remco Enthoven, and Steve Cichorsky.

Please send a file to add your name to this list!

Who's online

We have 804 guests online